FAS Compressor Technology for LPG Print

Blackmer Compressor 161 FAS-/Blackmer Compressor Unit 942 Mobile FAS-/Blackmer Compressor Unit 361
Blackmer Compressor 161 FAS-/Blackmer Compressor Unit 942 Mobile FAS-/Blackmer Compressor Unit 361

The FAS compressors for liquefied petroleum gas (LPG) are used for transshipment of product deliveries e.g. in tank farms as well as on road tankers and for extraction out of the storage tanks at site so that afterwards the tanks may be opened or transported. Depending on compressor model the displacement varies between 3,4 and 704 m3 per hour. The working range is max. 31 bar.


FAS compressors are available in following executions:

 - Single compressor, e.g. for installation in a road tanker

 - Stationary compressor unit with electric motor or Diesel engine

 - Mobile compressor unit with electric motor or Diesel engine, mounted on a trailer

 - Complete compressor stations including piping, control and monitoring unit

 - As an option each model is available with double piston rod seals as well as with
   “vibration certificate” for executions from 100 m³/hr onwards.


FAS Compressor units with Blackmer compressor, single-stage, vertical execution: FAS Compessor units with Corken compressor, single-stage vertical execution:
Type: Piston displacement: Type: Piston displacement:
- FAS-/Blackmer-161 3,4 up to max. 28 m³/Std. - FAS-/Corken-91 7,0 up to max. 14,3 m³/Std.
- FAS-/Blackmer-162 3,4 up to max. 28 m³/Std. - FAS-/Corken-291 13,9 up to max. 28,7 m³/Std.
- FAS-/Blackmer-361 7,3 up to max. 60,3 m³/Std. - FAS-/Corken-491 29,7 up to max. 61,2 m³/Std.
- FAS-/Blackmer-362 7,3 up to max. 60,3 m³/Std. - FAS-/Corken-691 50,1 up to max. 103,3 m³/Std.
- FAS-/Blackmer-601 13,1 up to max. 107,9 m³/Std. - FAS-/Corken-891 96,3 up to max. 198,8 m³/Std.
- FAS-/Blackmer-602 13,1 up to max. 107,9 m³/Std.
- FAS-/Blackmer-942 25,38 up to max. 209 m³/Std.


FAS Compressor units with Corken compressor, single-stage, horizontal execution with one cylinder:

FAS Compressor units with Corken compressor, single-stage, horizontal execution with two cylinders:

Type: Piston displacement: Type: Piston displacement:
- FAS-/Corken-HG601AX 116,9 up to max. 351,7 m³/Std. - FAS-/Corken-HG601AA 234,5 up to max. 704,0 m³/Std.
- FAS-/Corken-THG601AX 116,9 up to max. 351,7 m³/Std. - FAS-/Corken-THG601AA 234,5 up to max. 704,0 m³/Std.
- FAS-/Corken-HG601BX 65,2 up to max. 195,4 m³/Std. - FAS-/Corken-HG601BB 130,5 up to max. 393,0 m³/Std.
- FAS-/Corken-THG601BX 65,2 up to max. 195,4 m³/Std. - FAS-/Corken-THG601BB 130,5 up to max. 393,0 m³/Std.
- FAS-/Corken-HG601CX 44,9 up to max. 134,4 m³/Std. - FAS-/Corken-HG601CC 89,7 up to max. 268,8 m³/Std.
- FAS-/Corken-THG601CX 44,9 up to max. 134,4 m³/Std. - FAS-/Corken-THG601CC 89,7 up to max. 268,8 m³/Std.
- FAS-/Corken-HG601DX 28,5 up to max. 84,6 m³/Std. - FAS-/Corken-HG601DD 56,4 up to max. 169,2 m³/Std.
- FAS-/Corken-THG601DX 28,5 up to max. 84,6 m³/Std. - FAS-/Corken-THG601DD 56,4 up to max. 169,2 m³/Std.
- FAS-/Corken-HG601EX 18,3 up to max. 54,5 m³/Std. - FAS-/Corken-HG601EE 36,0 up to max. 108,7 m³/Std.
- FAS-/Corken-THG601EX 18,3 up to max. 54,5 m³/Std. - FAS-/Corken-THG601EE 36,0 up to max. 108,7 m³/Std.
- FAS-/Corken-HG601FX 12,9 up to max. 56,0 m³/Std. - FAS-/Corken-HG601FF 25,1 up to max. 75,6 m³/Std.
- FAS-/Corken-THG601FX 12,9 up to max. 56,0 m³/Std. - FAS-/Corken-THG601FF 25,1 up to max. 75,6 m³/Std.


FAS Compressor units with Corken compressor, two-stage, horizontal execution with one cylinder:

FAS Compressor units with Corken compressor, two-stage, horizontal execution with two cylinders:

Type: Piston displacement: Type: Piston displacement:
- FAS-/Corken-HG602AB 116,9 up to max. 351,7 m³/Std. - FAS-/Corken-HG602BE 65,2 up to max. 134,4 m³/Std.
- FAS-/Corken-THG602AB 116,9 up to max. 351,7 m³/Std. - FAS-/Corken-THG602BE 65,2 up to max. 134,4 m³/Std.
- FAS-/Corken-HG602AC 116,9 up to max. 351,7 m³/Std. - FAS-/Corken-HG602CD 44,9 up to max. 134,4 m³/Std.
- FAS-/Corken-THG602AC 116,9 up to max. 351,7 m³/Std. - FAS-/Corken-THG602CD 44,9 up to max. 134,4 m³/Std.
- FAS-/Corken-HG602AD 116,9 up to max. 351,7 m³/Std. - FAS-/Corken-HG602CF 44,9 up to max. 134,4 m³/Std.
- FAS-/Corken-THG602AD 116,9 up to max. 351,7 m³/Std. - FAS-/Corken-THG602CF 44,9 up to max. 134,4 m³/Std.
- FAS-/Corken-HG602BC 65,2 up to max. 195,4 m³/Std. - FAS-/Corken-HG602DE 28,5 up to max. 84,6 m³/Std.
- FAS-/Corken-THG602BC 65,2 up to max. 195,4 m³/Std. - FAS-/Corken-THG602DE 28,5 up to max. 84,6 m³/Std.
- FAS-/Corken-HG602BD 65,2 up to max. 195,4 m³/Std. - FAS-/Corken-HG602DF 28,5 up to max. 84,6 m³/Std.
- FAS-/Corken-THG602BD 65,2 up to max. 195,4 m³/Std.) - FAS-/Corken-THG602DF 28,5 up to max. 84,6 m³/Std.
- FAS-/Corken-HG602BF 65,2 up to max. 195,4 m³/Std. - FAS-/Corken-HG602EF 18,3 up to max. 54,5 m³/Std.
- FAS-/Corken-THG602BF 65,2 up to max. 195,4 m³/Std. - FAS-/Corken-THG602EF 18,3 up to max. 54,5 m³/Std.

Additionally we offer:

- Planning and design

- Project-related system control

- Complete installation and commissioning

- Service and maintenance


FAS-/Corken Compressor Unit 291 with Diesel engine Station with FAS-/Corken Compressor Units 891 FAS-/Corken Compressor Unit  Horizontal HG 601 BB
FAS-/Corken Compressor Unit 291 with Diesel engine Station with FAS-/Corken Compressor Units 891 FAS-/Corken Compressor Unit Horizontal HG 601 BB